main
OPTION PARTS LIST
Download documentation
(CAD data, etc.)
Blower
Direct Drive Blowers
For other option products,
please contact us.
please contact us.
Contact us
-
Discharge SilencersAttach to the blower discharge port to reduce noise.
LEARN MORE
-
Intake SilencersAttach to the blower intake port to reduce noise.
LEARN MORE
-
Intake FiltersCollects contaminants such as dust from intake air.
LEARN MORE
-
Butterfly DampersInstall on the intake or discharge ports to adjust airflow.
LEARN MORE
-
Vibration Damping ConnectorsUse to connect ducts to the intake or discharge ports to reduce vibration.
LEARN MORE
-
Vibration damping standAbsorbs blower vibrations.
LEARN MORE
-
Connecting pipe for
bottom vertical suctionIt is easy to install when the blower is installed with the suction port facing downward.LEARN MORE
Discharge Silencers
Attach to the blower discharge port to reduce noise.
Standard Specifications
Model | External Dimensions(mm) | Installation section dimensions(mm) | Compatible Models | ||||||
---|---|---|---|---|---|---|---|---|---|
φA | L | I | φd | φD | φE | Z | |||
3YD-2 | A | 240 | 650 | 506 | 63 | 92 | 81 | 7 | E●-63 |
B | 75 | 108 | 94 | 7 | E●-75, SF-75, SB-75, U75-H■ | ||||
C | 136 | 120 | 8 | KSB-H04 | |||||
3YD-3 | B | 290 | 650 | 506 | 100 | 136 | 120 | 7 | E●-04S, E●-H04, EM-H07, AH-400 |
C | 140 | 125 | 8 | FSM-04S, FSM-H04, U100B-H■ | |||||
3YD-4 | B | 315 | 1200 | 1006 | 125 | 170 | 152 | 10 | E●-H07, E●-H10, EM-H22, FSM-H07, KSB-H07(B)/H15(B), AH-H04 |
C | 150 | 200 | 180 | 10 | E●-H15, KSB-H22(B) | ||||
3YD-5 | B | 340 | 1200 | 1006 | 175 | 230 | 210 | 10 | KSB-H37(B) |
※ The "●" following "E" in the Standard Specifications table means that either a C, P, or M may appear there.
※ The "●" following "U75-H" means either a 2, 3, 4, or 5 may appear there.
※ The "●" following "U100B-H" means either a 2, 3, 4, or 5 may appear there.
※ An HT at the end of a model number indicates a heat-resistant model. Example: 3YD-2AHT
Intake Silencers
Attach to the blower intake port to reduce noise.
Attached to U75-H3 set, with legs (optional)
Attached to U75-H3 set, with legs (optional)
Standard Specifications
Model | External Dimensions(mm) | Installation section dimensions(mm) | Compatible Models | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
φA | B | B1 | B2 | L | φd | φD | φE | Z | |||
YS-2 | B1 | 250 | 230 | 170 | 60 | 260 | 100 | 136 | 120 | 7 | E●-63, E●-75 |
C1 | 156 | 140 | SF-75※, SB-75※ | ||||||||
YS-3 | C1 | 315 | 250 | 180 | 70 | 280 | 115 | 156 | 140 | 7 | FSM-04S, FSM-H04 |
C2 | AH-400 | ||||||||||
YS-4 | D2 | 400 | 270 | 190 | 80 | 300 | 150 | 200 | 180 | 10 | AH-H04 |
F | 160 | 230 | 210 | AH-H07 | |||||||
YS-5 | H | 500 | 290 | 200 | 90 | 320 | 200 | 260 | 240 | 10 | AH-H10 |
YS-6 | E | 630 | 310 | 210 | 100 | 340 | 250 | 300 | 280 | 8-8φ | AH-H15 |
3YS-3 | B | 315 | 250 | 180 | 70 | 280 | 115 | 156 | 136/140 | 6x8 Slot | E●-04S, E●-H04, EM-H07, U75-H■ |
3YS-4 | B | 400 | 270 | 190 | 180 | 300 | 100 | 170 | 152 | 10 | KSB-H04 |
D | 150 | 210 | 180 | E●-H07/H10/H15, EM-H22, FSM-H07, U100B-H■ | |||||||
3YS-5 | D | 500 | 290 | 200 | 90 | 320 | 160 | 230 | 210 | 10 | KSB-H07(B), KSB-H15(B), KSB-H22(B) |
3YS-6 | C | 630 | 310 | 210 | 100 | 340 | 190 | 260 | 240 | 10 | KSB-H37(B) |
F | 275 | 325 | 305 | 8-8φ | AH-H22 | ||||||
3YS-8 | - | 800 | 320 | 220 | 100 | 430 | 300 | 355 | 335 | 8-10φ | AH-H37 |
※ Models marked with an asterisk require tapping on the blower side to install.
※ An OD at the end of a model number indicates an outdoor-use specification. Example: 3YS-3B-
Intake Filters
Collects contaminants such as dust from intake air.
Attached to AH-H04
Attached to AH-H04
Standard Specifications
Model | External Dimensions(mm) | Installation section dimensions(mm) | Compatible Models | ||||||
---|---|---|---|---|---|---|---|---|---|
φA | B | L | C | φd | P.C.D | φz | |||
3FM-2 | A | 250 | 160 | 60 | 34 | 100 | 120 | 6 | E●-63, E●-75 |
B | 125 | 136/140 | SF-75※, SB-75※, FS-200, U75-H■ | ||||||
3FM-3 | A | 315 | 170 | 75 | 33 | 125 | 140 | 6 | E●-04S, E●-H04, EM-H07, FSM-04S, FSM-H04, AH-400, FS-H04 |
B | 152 | 10 | KSB-H04 | ||||||
3FM-4A | 400 | 200 | 90 | 32 | 150 | 180 | 10 | E●-H07/H10/H15, AH-H04, EM-H22, FSM-H07, FS-H07/H15, U100B-H | |
3FM-5A | 500 | 230 | 110 | 32 | 170 | 210 | 10 | KSB-H07(B)/H15(B)/H22(B), AH-H07, FS-H22 | |
3FM-6 | A | 600 | 300 | 120 | 33 | 220 | 240/250 | 10/6.3 | KSB-H37(B), AH-H10 |
B | 265 | 280 | 8-6.3 | AH-H15 |
※Models marked with an asterisk require tapping on the blower side to install.
Butterfly Dampers
Install on the intake or discharge ports to adjust airflow.
Round type
Model | Dimension L(mm) | Compatible Models | ||
---|---|---|---|---|
Discharge side | Intake side | |||
D-63 | B | 220 | E●-63 | |
D-75 | B | 120 | E●-75, SF-75, SB-75, U75-H■ | |
C | KSB-H04 | |||
D-100 | B | 220 | E●-04S, E●-H04, EM-H07, AH-400 | E●-63, E●-75, FS-150 |
C | FSM-04S, FSM-H04, U100B-H■ | |||
D-125 | B | 220 | U75-H■ | |
C | E●-04S, E●-H04, EM-H07, FS-200, FS-H04, FSM-04S, FSM-H04, AH-400, SF-75※, SB-75 | |||
D | E●-H07, E●-H10, EM-H22, FSM-H07, KSB-H07(B)/H15(B), AH-H04 | KSB-H04 | ||
D-150 | C | 220 | E●-H15, KSB-H22(B) | E●-H07/H10/H15, EM-H22, AH-H04, FSM-H07, U100B-H■ |
D-175 | D | 220 | KSB-H37(B) | AH-H07, KSB-H07(B)/H15(B)/H22(B) |
D-200 | C | 220 | AH-H10, KSB-H37(B) | |
D-250 | B | 250 | AH-H15 | |
D-275 | B | 300 | AH-H22 | |
D-300 | B | 300 | AH-H37 |
Rectangular type (for discharge)
Model | Dimension L(mm) | Dimension B(mm) | Compatible Models |
---|---|---|---|
D-S144B | 220 | 200 | AH-H07 |
D-S160B | 220 | 216 | AH-H10 |
D-S180B | 220 | 236 | AH-H15 |
D-S210B | 220 | 260 | AH-H22 |
D-S240B | 250 | 290 | AH-H37 |
※ An HT at the end of a model number indicates a heat-resistant model. Example: D-63BHT
Vibration Damping Connectors
Use to connect ducts to the intake or discharge ports to reduce vibration.
Round type
Model | Dimension L(mm) | Compatible Models | ||
---|---|---|---|---|
Discharge side | Intake side | |||
C-63 | B | 120 | E●-63 | |
C-75 | B | 120 | E●-75, SF-75, SB-75, U75-H■ | |
C | KSB-H04 | |||
C-100 | B | 180 | E●-04S, E●-H04, EM-H07, AH-400 | E●-63, E●-75, FS-150 |
C | FSM-04S, FSM-H04, U100B-H■ | |||
C-125 | B | 180 | U75-H■ | |
C | E●-04S, E●-H04, EM-H07, FS-200, FS-H04, FSM-04S, FSM-H04, SF-75※, SB-75※, AH-400 | |||
D | E●-H07, E●-H10, EM-H22, FSM-H07, KSB-H07(B)/H15(B), AH-H04 | KSB-H04 | ||
C-150 | C | 180 | E●-H15, KSB-H22(B) | E●-H07/H10/H15, EM-H22, AH-H04, FS-H07,FS-H15, FSM-H07, U100B-H■ |
C-175 | D | 180 | KSB-H37(B) | AH-H07, KSB-H07(B)/H15(B)/H22(B), FS-H22 |
C-200 | C | 180 | AH-H10, KSB-H37(B) | |
C-250 | B | 180 | AH-H15 | |
C-275 | B | 180 | AH-H22 | |
C-300 | B | 180 | AH-H37 |
Rectangular type (for discharge)
Model | Dimension B(mm) | Compatible Models |
---|---|---|
C-S144B | 200 | AH-H07 |
C-S160B | 216 | AH-H10 |
C-S180B | 236 | AH-H15 |
C-S210B | 260 | AH-H22 |
C-S240B | 290 | AH-H37 |
Vibration damping stand
Absorbs blower vibrations.
Model | Compatible Models | Dimension L(mm) | Vibration damping rubber | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
A | B | C | D | E | F | G | Z | ||||
B-2 | B | E●-63 | 100 | 180 | 280 | 310 | 59 | 250 | 280 | 12 | KA-12 |
C | E●-75 | ||||||||||
D | SF-75, SB-75 | ||||||||||
E | FSM-04S | ||||||||||
B-3 | B | E●-04S, E●-H04, EM-H07, FSM-H04 |
125 | 235 | 360 | 390 | 63 | 320 | 350 | 12 | KA-20-20h |
D | AH-400 | ||||||||||
E | AH-H04 | ||||||||||
B-3U | 2 | U75-H2 | 185 | 235 | 420 | 450 | 63 | 320 | 350 | 12 | |
3 | U75-H3 | 255 | 490 | 520 | |||||||
4 | U75-H4 | 325 | 560 | 590 | |||||||
5 | U75-H5 | 395 | 630 | 660 | |||||||
B-4 | B | FSM-H07 | 160 | 290 | 450 | 480 | 72 | 400 | 430 | 12 | KA-25-27h |
C | EC-H07, EP-H07 | ||||||||||
D | E●-H15 | ||||||||||
E | AH-H07 | ||||||||||
F | AH-H10 | ||||||||||
G | KSB-H04 | ||||||||||
J | E●-H10, EM-H22 | ||||||||||
B-5 | C | KSB-H07(B) | 200 | 360 | 560 | 590 | 71 | 500 | 530 | 12 | KA-30-26h |
D | KSB-H15(B) | ||||||||||
F | AH-H15 | ||||||||||
B-6 | B | KSB-H22(B) | 270 | 440 | 710 | 740 | 78 | 630 | 660 | 12 | KA-40-33h |
C | KSB-H37(B) | ||||||||||
G | AH-H22 | ||||||||||
B-7 | B | AH-H37 | 280 | 520 | 800 | 830 | 78 | 710 | 750 | 12 |
※ An HT at the end of a model number indicates a heat-resistant model. Example: B-2BHT
Connecting pipe for bottom vertical suction
It is easy to install when the blower is installed with the suction port facing downward.
Model | Dimension (mm) | Compatible Models | |||||
---|---|---|---|---|---|---|---|
ΦA | ΦB | C | D | ΦE | F | ||
JB-125C | Φ154 | Φ115 | 100 | 4.5 | Φ140 | 2x4-Φ7 | EC-H04, EP-H04, EM-H07 |
JB-125D | Φ170 | Φ125 | 100 | 4.5 | Φ152 | 2x4-Φ10 | KSB-H04 |
JB-150C | Φ200 | Φ150 | 100 | 4.5 | Φ180 | 2x4-Φ10 | EC-H07, EP-H07, EM-H10 |
JB-175D | Φ230 | Φ170 | 100 | 4.5 | Φ210 | 2x4-Φ10 | KSB-H07 (B) |
※ Heat-resistant type is named with HT at the end of the model. (e.g., JB-125CHT)
※ Please contact us for support for compatible models other than those listed above.
※ Please contact us for support for compatible models other than those listed above.
Inquiry about our products
Use this form to request a quote for this product, as well as submit product and technology questions, malfunction and repairs questions, and other general inquiries.
Contact us