Environmental Equipment
Mist Collectors
Mistresa Multi-select Type Vertical ( CRM-V )
The CRM vertical type (CRM-V type) is a compact specification that does not need piping. As well, it is available in filterless and filter versions, so that customers can select the best option for their application.
Online Catalog
PDF documentation and CAD data for this product are available for download.
-
General Catalogs
-
-
Manuals
-
Performance
Curves-
SCROLL or SWYPE
-
CRM-H02-V11
-
CRM-H02-V12
-
CRM-H02-V13
-
CRM-H02-V21
-
CRM-H02-V22
-
CRM-H02-V23
-
CRM-H04-V11
-
CRM-H04-V12
-
CRM-H04-V13
-
CRM-H04-V21
-
CRM-H04-V22
-
CRM-H04-V23
-
CRM-H07-V11
-
CRM-H07-V12
-
CRM-H07-V13
-
CRM-H07-V21
-
CRM-H07-V22
-
CRM-H07-V23
-
CRM-H15-V11
-
CRM-H15-V12
-
CRM-H15-V13
-
CRM-H15-V21
-
CRM-H15-V22
-
CRM-H15-V23
-
CRM-H22-V11
-
CRM-H22-V12
-
CRM-H22-V13
-
CRM-H22-V21
-
CRM-H22-V22
-
CRM-H22-V23
-
SCROLL or SWYPE
-
-
External Dimensions
Drawings-
SCROLL or SWYPE
-
CRM-H02-V11
-
CRM-H02-V12
-
CRM-H02-V13
-
CRM-H02-V21
-
CRM-H02-V22
-
CRM-H02-V23
-
CRM-H04-V11
-
CRM-H04-V12
-
CRM-H04-V13
-
CRM-H04-V21
-
CRM-H04-V22
-
CRM-H04-V23
-
CRM-H07-V11
-
CRM-H07-V12
-
CRM-H07-V13
-
CRM-H07-V21
-
CRM-H07-V22
-
CRM-H07-V23
-
CRM-H15-V11
-
CRM-H15-V12
-
CRM-H15-V13
-
CRM-H15-V21
-
CRM-H15-V22
-
CRM-H15-V23
-
CRM-H22-V11
-
CRM-H22-V12
-
CRM-H22-V13
-
CRM-H22-V21
-
CRM-H22-V22
-
CRM-H22-V23
-
SCROLL or SWYPE
-
-
External Dimensions
Drawings-
SCROLL or SWYPE
-
CRM-H02-V11
-
CRM-H02-V12
-
CRM-H02-V13
-
CRM-H02-V21
-
CRM-H02-V22
-
CRM-H02-V23
-
CRM-H04-V11
-
CRM-H04-V12
-
CRM-H04-V13
-
CRM-H04-V21
-
CRM-H04-V22
-
CRM-H04-V23
-
CRM-H07-V11
-
CRM-H07-V12
-
CRM-H07-V13
-
CRM-H07-V21
-
CRM-H07-V22
-
CRM-H07-V23
-
CRM-H15-V11
-
CRM-H15-V12
-
CRM-H15-V13
-
CRM-H15-V21
-
CRM-H15-V22
-
CRM-H15-V23
-
CRM-H22-V11
-
CRM-H22-V12
-
CRM-H22-V13
-
CRM-H22-V21
-
CRM-H22-V22
-
CRM-H22-V23
-
SCROLL or SWYPE
-
-
Please contact us regarding other documentation
Features
- 1. Filterless and filter versions mean you can choose the best option for your application.
- The multi-select type offers six different combinations per machine model. (Utility model registration pending)
-
About Multi-Select
-
Multi-Select
Motor output from 0.2 kW to 2.2 kW, two types of parts on the filter box side, three types of parts on the main unit side, and horizontal and vertical options mean we can deliver, in a short time frame, any one of 60 combinations optimized for your company's needs."The perfect Mistresa product for every customer": A mix and match mist collector.Front Parts - Front Demister
-
(Mainly compatible with water-soluble cutting fluids)
- Front Filter
-
(Mainly compatible with oil-based cutting fluids)
Back Parts - Tapered Tube
-
(Mainly compatible with water-soluble cutting fluids)
- End Demister
-
(Mainly compatible with water-soluble cutting fluids)
- End Filter
-
(Mainly compatible with oil-based cutting fluids)
By changing these combinations, a single machine can be transformed into one of six types in order to meet usage conditions (customers choose interior parts to match cutting conditions and cutting fluid specifications).
- 2. Includes our own manufactured top runner motor IE3
- (0.2kW、0.4kW excluded)
- 3. No need for duct hose or drain tube
- 4. CE compatible
- At customer request, we can build CE specification products.
- 5. Motor with burnout protection terminal
- A thermal protector is attached to the motor coil, and this is connected to the operating circuit of the electromagnetic switch in order to prevent burnout.
- 6. Excellent motor
- Our safe designs use IP65-grade protection (dust resistance, sprayed water protection models).
Applications
specification
Standard Specifications
Model explained
Model ( → Model explained ) | CRM-H02-V□□ | CRM-H04-V□□ | CRM-H07-V□□ | CRM-H15-V□□ | CRM-H22-V□□ |
---|---|---|---|---|---|
Power Supply | Three phase 50Hz200V 60Hz200V/220V | ||||
Output (kW) | 0.2 | 0.4 | 0.75 | 1.5 | 2.2 |
Heat-resistant class | 130 (B) | 130 (B) | 155 (F) | 155 (F) | |
Frequency (Hz) | 50/60/60 | ||||
Current (A) | 1.6/1.3/1.3 | 2.0/2.0/2.0 | 3.0/3.3/3.3 | 6.9/7.0/7.0 | 10.2/10.4/10.4 |
Weight (kg) | 27 | 34 | 43 | 69 | 78 |
Intake Port Diameter (mm) | ∅100 | ∅100 | ∅125 | ∅150 | ∅200 |
Ambient Temperature (℃) | 0 to 50 | ||||
Maximum Intake Temperature (℃) | 50 |
Specifications by Type
Model | 50Hz | 60Hz | Collection Efficiency (%) | ||||
---|---|---|---|---|---|---|---|
Maximum Airflow (m3/min) | Maximum Static Pressure (kPa) | Noise※1 Machine side1m dB(A) | Maximum Airflow (m3/min) | Maximum Static Pressure (kPa) | Noise※1 Machine side1m dB(A) | ||
CRM-H02-V11 | 3.7 | 0.55 | 61 | 4.4 | 0.75 | 65 | 98.7 |
CRM-H02-V12 | 4.5 | 63 | 5.3 | 66 | 99.2 | ||
CRM-H02-V13 | 3.9 | 60 | 4.6 | 64 | 99.7 | ||
CRM-H02-V21 | 3.4 | 60 | 4 | 64 | 98.8 | ||
CRM-H02-V22 | 4.1 | 62 | 4.8 | 66 | 99.4 | ||
CRM-H02-V23 | 3.5 | 59 | 4.2 | 62 | 99.7 | ||
CRM-H04-V11 | 4 | 0.7 | 67 | 4.7 | 1 | 71 | 98.7 |
CRM-H04-V12 | 5 | 71 | 5.9 | 75 | 99.2 | ||
CRM-H04-V13 | 4.4 | 69 | 5.2 | 71 | 99.7 | ||
CRM-H04-V21 | 3.8 | 66 | 4.4 | 69 | 98.8 | ||
CRM-H04-V22 | 4.6 | 68 | 5.5 | 72 | 99.4 | ||
CRM-H04-V23 | 4.1 | 67 | 4.9 | 70 | 99.7 | ||
CRM-H07-V11 | 7.4 | 1 | 73 | 8.6 | 1.45 | 77 | 98.7 |
CRM-H07-V12 | 9 | 77 | 10.5 | 81 | 99.2 | ||
CRM-H07-V13 | 7.6 | 72 | 9 | 76 | 99.7 | ||
CRM-H07-V21 | 6.8 | 72 | 8.2 | 76 | 98.8 | ||
CRM-H07-V22 | 8.4 | 73 | 10 | 77 | 99.4 | ||
CRM-H07-V23 | 7 | 70 | 8.4 | 74 | 99.7 | ||
CRM-H15-V11 | 14 | 1.5 | 77 | 17 | 2.15 | 80 | 98.7 |
CRM-H15-V12 | 16 | 78 | 19 | 83 | 99.2 | ||
CRM-H15-V13 | 14 | 76 | 17 | 79 | 99.7 | ||
CRM-H15-V21 | 13.5 | 75 | 15.5 | 78 | 98.8 | ||
CRM-H15-V22 | 15 | 77 | 18 | 80 | 99.4 | ||
CRM-H15-V23 | 13.5 | 76 | 15.5 | 78 | 99.7 | ||
CRM-H22-V11 | 19.5 | 1.6 | 79 | 22.5 | 2.3 | 83 | 98.7 |
CRM-H22-V12 | 22 | 81 | 26 | 85 | 99.2 | ||
CRM-H22-V13 | 19 | 77 | 22.5 | 81 | 99.7 | ||
CRM-H22-V21 | 18 | 77 | 21 | 81 | 98.8 | ||
CRM-H22-V22 | 21 | 80 | 24.5 | 84 | 99.4 | ||
CRM-H22-V23 | 17.5 | 76 | 21 | 79 | 99.7 |
Accessories
Hanger bolt x 2 | ○ |
---|---|
Crimp-style terminal x 7 (1 spare) | ○ |
Expendables
Item Name | CRM-H02-V | CRM-H04-V | CRM-H07-V | CRM-H15-V | CRM-H22-V | |
---|---|---|---|---|---|---|
Front Demister | Model | 3KFD-H04V | 3KFD-H04V | 3KFD-H07V | 3KFD-H15V | 3KFD-H22V |
Product Code | 10012761 | 10012761 | 10012763 | 10012765 | 10012767 | |
Front Filter | Model | 3KFF-H04V | 3KFF-H04V | 3KFF-H07V | 3KFF-H15V | 3KFF-H22V |
Product Code | 10012753 | 10012753 | 10012755 | 10012757 | 10012759 | |
End Demister | Model | 3KED-H04V | 3KED-H04V | 3KED-H07V | 3KED-H15V | 3KED-H22V |
Product Code | 10012796 | 10012796 | 10012797 | 10012798 | 10012799 | |
End Filter | Model | 3KEF-H04 | 3KEF-H04 | 3KEF-H07 | 3KEF-H15 | 3KEF-H22 |
Product Code | 10012772 | 10012772 | 10012773 | 10012774 | 10012775 |
Options
Comparison Table of Models
Filterless Types (water-soluble mist compatible)
Output (kW) | 2005/12 to 2013/10 | 2013/04 to 2017/03 | 2017/01 to |
---|---|---|---|
0.2 | --- | CRM-H02-S11, S12 | |
0.4 | CRX-04NS | CRN-H04B | CRM-H04-S11, S12 |
0.75 | CRX-07NS | CRN-H07B | CRM-H07-S11, S12 |
1.5 | CRX-15NS | CRN-H15B | CRM-H15-S11, S12 ※ |
2.2 | CRX-22NS | --- | CRM-H22-S11, S12 |
Filter Types (water-soluble mist compatible)
Output (kW) | 1993/04 to 1996/06 | 1996/06 to 2005/11 | 2001/12 to 2004/06 | 2004/02 to 2015/03 | 2015/02 to 2017/03 | 2017/01 to |
---|---|---|---|---|---|---|
0.2 | --- | CRM-H02-S22, S23 | ||||
0.4 | CR-400 | CR-400K | CRD-400K | CRD-400R | CRD-H04 | CRM-H04-S22, S23 |
0.75 | CR-750 | CR-750K | CRD-750K | CRD-750R | CRD-H07 | CRM-H07-S22, S23 |
1.5 | CR-1500 | CR-1500K | CRD-1500K | CRD-1500R | CRD-H15 | CRM-H15-S22, S23 |
2.2 | --- | CRD-2200K | CRD-2200R | CRD-H22 | CRM-H22-S22, S23 |
Filter Types (oil mist compatible)
Output (kW) | 1993/04 to 1996/06 | 1996/06 to 2005/11 | 2004/02 to 2015/03 | 2015/02 to 2017/03 | 2017/01 to |
---|---|---|---|---|---|
0.2 | --- | CRM-H02-S23 + After filter |
|||
0.4 | CR-400 + After filter |
CR-400K + After filter |
CRD-400R + After filter |
CRD-H04-80 + After filter |
CRM-H04-S23 + After filter |
0.75 | CR-750 + After filter |
CR-750K + After filter |
CRD-750R + After filter |
CRD-H07-80 + After filter |
CRM-H07-S23 + After filter |
1.5 | CR-1500 + After filter |
CRD-1500K + After filter |
CRD-1500R + After filter |
CRD-H15-80 + After filter |
CRM-H15-S23 + After filter |
2.2 | --- | CRD-2200R + After filter |
CRD-H22-80 + After filter |
CRM-H22-S23 + After filter |
For Your Safety
- ● Do not install in dangerous locations
- The Mistresa is not built as a pressure-resisting, explosion-proof device. When operated in locations with explosive gases present, motor burnout may ignite the gases, causing an explosion.
- ● To avoid fires and explosions
- Do not attempt to suck up explosive gases, organic solvents, or flames.
- ● To avoid fires and electric shock
- Mistresa wiring installation must be performed by a qualified electrician in accordance with electrical equipment technical standards and internal wiring regulations.
- ● Do not perform maintenance/inspections while operating
- All fans should be stopped before attempting to replace filters or perform inspections.
Product contacts
Contact us