main

Environmental Equipment
Ventilation equipments

Ventiresa Horizontal Flow Type ( PPHTF / PPHW / PPHWF )

Ventiresa
Harmful substances can be generated at work sites where chemical substances are manufactured and handled. Venitresa machines draw these substances into ventilation hoods before they can diffuse. By controlling the diffusion and spread of the substances, the machines make the work environment more comfortable.
PPHTF, PPHW, and PPHWF types are ventilation systems with hoods arranged left and right that generate a horizontal airflow. The controlled, uniform air flow moves across the work table to prevent the diffusion of harmful substances. The unit is configured to be open at the front, back, and above, so that it can be used in a range of situations.
For details, see our online catalog.
Online Catalog

Online Catalog

blank
PDF documentation and CAD data for this product are available for download.Download
※ Unpack ZIP packages to view the content. The content may consist of PDF or CAD data.
※ CAD data is in dxf format. Use a specialized CAD application or similar to view the file.
Features
A ventilation system with hoods arranged left and right to generate a horizontal airflow. The controlled, uniform air flow moves across the work table to prevent the diffusion of harmful substances. The unit is configured to be open at the front, back, and above, so that it can be used in a range of situations.
PPHTF
Horizontal flow table type
Horizontal work table series
PPHTF
PPHW
Horizontal flow wall type
Wall type series
PPHW
PPHWF
Horizontal flow wall type
Wall type series
(Built-in push blower)
PPHWF
Applications
Industrial robots of all kinds
Industrial robots of all kinds
Inkjet printers
Inkjet printers
Filling / conveyance
Filling / conveyance
Components analysis
Components analysis
Specifications
PPHTF

Model explained

 
Swype Swype
Seated work table (table height of 700 mm)
Model Dimension (mm) Duct diameter (φ) Approximate Weight (Kg) Reference power consumption (W)
PPHTF-0606SI W1100・H600・D600・L600 150 105 750
PPHTF-0707SI W1550・H750・D750・L1050 200 135 1000
PPHTF-0907SI W1700・H750・D900・L1200 200 145 1000
PPHTF-1207SI W1700・H750・D1200・L1200 250 165 1300
PPHTF-1507SI W2000・H750・D1500・L1500 250 190 1800
PPHTF-1807SI W2300・H750・D1800・L1800 300 210 2000
Size
※ 200 V AC, 3-phase
※ We can build to other dimensions as well.
Standing work table (table height of 900 mm)
Model Dimension (mm) Duct diameter (φ) Approximate Weight (Kg) Reference power consumption (W)
PPHTF-0606ST W1100・H600・D600・L600 150 105 750
PPHTF-0707ST W1550・H750・D750・L1050 200 135 1000
PPHTF-0907ST W1700・H750・D750・L1200 200 145 1000
PPVTF-1207ST W1700・H750・D1200・L1200 250 165 1300
PPHTF-1507ST W2000・H750・D1500・L1500 250 195 1800
PPHTF-1807ST W2300・H750・D1800・L1800 300 215 2000
Size
※ 200 V AC, 3-phase
※ We can build to other dimensions as well.
Construction equipment
Push Hood Built-in
Air Supply Blower Built-in
Pull Hood Built-in
Exhaust Blower Included (installed separately)
Control Panel Installed separately
PPHW
Swype Swype
Model Dimension (mm) L (mm) Duct diameter (φ) Approximate Weight (Kg) Recommended Blower (pull side) Reference power consumption (W)
PPHW-0303 W300・H300・D250 1200 125 40 MDF-AH-400 400
PPHW-0403 W450・H300・D250 1200 125 45 MDF-AH-400 400
PPHW-0603 W600・H300・D250 1200 125 50 MDF-AH-400 400
PPHW-0703 W750・H300・D250 1200 125 55 MDF-AH-400 400
PPHW-0903 W900・H300・D250 1200 150 60 MDF-AH-500 800
PPHW-0404 W450・H450・D250 1800 125 50 MDF-AH-400 400
PPHW-0604 W600・H450・D250 1800 150 60 MDF-AH-500 800
PPHW-0704 W750・H450・D250 1800 150 65 MDF-AH-500 800
PPHW-0904 W900・H450・D250 1800 150 70 MDF-AH-500 800
PPHW-1204 W1200・H450・D450 1800 200 80 MDF-AH-600 1500
PPHW-0606 W600・H600・D250 2400 150 65 MDF-AH-500 800
PPHW-0706 W750・H600・D250 2400 150 75 MDF-AH-500 800
PPHW-0906 W900・H600・D250 2400 200 80 MDF-AH-600 1500
PPHW-1206 W1200・H600・D450 2400 200 90 MDF-AH-600 1500
PPHW-1506 W1500・H600・D450 2400 250 105 MDF-AH-800 2000
PPHW-1806 W1800・H600・D450 2400 250 115 MDF-AH-1000 3000
PPHW-0707 W750・H750・D250 3000 200 85 MDF-AH-600 1500
PPHW-0907 W900・H750・D250 3000 200 90 MDF-AH-600 1500
PPHW-1207 W1200・H750・D450 3000 250 105 MDF-AH-800 2000
PPHW-1507 W1500・H750・D450 3000 250 115 MDF-AH-1000 3000
PPHW-1807 W1800・H750・D450 3000 300 130 MDF-AH-1000 3000
PPHW-0909 W900・H900・D250 3600 250 100 MDF-AH-800 2000
PPHW-1209 W1200・H900・D450 3600 250 115 MDF-AH-1000 3000
PPHW-1509 W1500・H900・D450 3600 300 130 MDF-AH-1200 4400
PPHW-1809 W1800・H900・D450 3600 300 145 MDF-AH-1200 4400
PPHW-1212 W1200・H1200・D450 4800 300 140 MDF-AH-1200 4400
PPHW-1512 W1500・H1200・D450 4800 300 155 MDF-AH-1200 4400
PPHW-1812 W1800・H1200・D450 4800 350 170 MDF-AH-H37 7400
PPHW-1515 W1500・H1500・D450 6000 350 180 MDF-AH-H37 7400
PPHW-1815 W1800・H1500・D450 6000 400 200 MDF-AH-H37 7400
PPHW-1818 W1800・H1800・D450 7200 400 230 MDF-AH-H37 7400
Size
Construction equipment
Push Hood Included
Air Supply Blower Sold separately
Pull Hood Included
Exhaust Blower Sold separately
Control Panel Sold separately
※ We can also make units with built-in air supply blowers
PPHWF
Swype Swype
Model Dimension (mm) L (mm) Duct diameter (φ) Approximate Weight (Kg) Recommended Blower (pull side) Reference power consumption (W)
PPHWF-0303 W300・H300・D250 1200 125 40 MDF-AH-400 300
PPHWF-0403 W450・H300・D250 1200 125 45 MDF-AH-400 300
PPHWF-0603 W600・H300・D250 1200 125 50 MDF-AH-400 300
PPHWF-0703 W750・H300・D250 1200 125 55 MDF-AH-400 300
PPHWF-0903 W900・H300・D250 1200 150 60 MDF-AH-500 500
PPHWF-0404 W450・H450・D250 1800 125 50 MDF-AH-400 300
PPHWF-0604 W600・H450・D250 1800 150 60 MDF-AH-500 500
PPHWF-0704 W750・H450・D250 1800 150 65 MDF-AH-500 500
PPHWF-0904 W900・H450・D250 1800 150 70 MDF-AH-500 600
PPHWF-1204 W1200・H450・D450 1800 200 80 MDF-AH-600 900
PPHWF-0606 W600・H600・D250 2400 150 65 MDF-AH-500 600
PPHWF-0706 W750・H600・D250 2400 150 75 MDF-AH-500 600
PPHWF-0906 W900・H600・D250 2400 200 80 MDF-AH-600 1000
PPHWF-1206 W1200・H600・D450 2400 200 90 MDF-AH-600 1100
PPHWF-1506 W1500・H600・D450 2400 250 105 MDF-AH-800 1100
PPHWF-1806 W1800・H600・D450 2400 250 115 MDF-AH-1000 1800
PPHWF-0707 W750・H750・D250 3000 200 85 MDF-AH-600 1000
PPHWF-0907 W900・H750・D250 3000 200 90 MDF-AH-600 1000
PPHWF-1207 W1200・H750・D450 3000 250 105 MDF-AH-800 1300
PPHWF-1507 W1500・H750・D450 3000 250 115 MDF-AH-1000 1800
PPHWF-1807 W1800・H750・D450 3000 300 130 MDF-AH-1000 2000
PPHWF-0909 W900・H900・D250 3600 250 100 MDF-AH-800 1300
PPHWF-1209 W1200・H900・D450 3600 250 115 MDF-AH-1000 1800
PPHWF-1509 W1500・H900・D450 3600 300 130 MDF-AH-1200 2700
PPHWF-1809 W1800・H900・D450 3600 300 145 MDF-AH-1200 2700
PPHWF-1212 W1200・H1200・D450 4800 300 145 MDF-AH-1200 2700
PPHWF-1512 W1500・H1200・D450 4800 300 160 MDF-AH-1200 2700
PPHWF-1812 W1800・H1200・D450 4800 350 175 MDF-AH-H37 4500
PPHWF-1515 W1500・H1500・D450 6000 350 185 MDF-AH-H37 4500
PPHWF-1815 W1800・H1500・D450 6000 400 205 MDF-AH-H37 4500
PPHWF-1818 W1800・H1800・D450 7200 400 235 MDF-AH-H37 4500
Size
Construction equipment
Push Hood Included
Air Supply Blower Built-in
Pull Hood Included
Exhaust Blower Sold separately
Control Panel Sold separately
※ Built-in push blower
Close
Model explained
Model explained
Risk Assessment of Chemical Substances
Working Environment Measurement Agency
As a blower manufacturer, we are a registered Working Environment Measurement Agency.
Registration No.:
27-112
We cover the entire process, from taking measurements of your work environment to installing equipment such as local exhaust ventilation.

What is a Working Environment
Measurement Agency?

blank

Installation Examples
Chemical plant
Chemical plant
Process: Mixing
Raw materials may contain toluene, styrene, and other additives. Ventilation and exhaust facilities are required to prevent such substances from spreading into the surroundings during mixing.
Semiconductor plant
Semiconductor plant
Process: Etching
Masking agents used in the etching process contain organic solvents such as trichlene. Ventilation and exhaust facilities are required to prevent such substances from spreading into the surroundings.
Pharmaceuticals plant
Pharmaceuticals plant
Process: Printing
The ink used when printing tablet packaging contains organic solvents such as methyl ethyl ketone. Ventilation and exhaust facilities are required to stop such solvents from spreading into the surroundings during printing.
Cosmetics plant
Cosmetics plant
Process: Mixing / filling
In order to maintain product quality, the vessels used in mixing and filling must be cleaned. The cleaning and disinfecting solutions contain organic solvents such as ethanol. Ventilation and exhaust facilities are required to stop workers from being exposed to such substances.
Product contacts